US FDA clearance: 510(k) and De Novo.

The 510(k) pathway remains the primary route for most Class II medical devices entering the US market. De Novo classification is used when no legally marketed predicate exists. We prepare defensible submissions that address FDA's current review standards and minimise the risk of an Additional Information (AI) request.

510(k)De NovoSubstantial EquivalencePredicate Strategy21 CFR Part 820
Predicate Strategy and 510(k) Pathway Selection

A 510(k) submission must demonstrate substantial equivalence to a legally marketed predicate device under Section 510(k) of the Federal Food, Drug, and Cosmetic Act and 21 CFR Part 807 Subpart E. Predicate selection is the single most consequential early decision — the wrong predicate can lead to an AI request or Not Substantially Equivalent (NSE) determination regardless of the quality of other submission elements.

We conduct a structured predicate search across the FDA 510(k) database, review 510(k) summaries and decision summaries for candidate predicates, and identify which predicate or predicate chain best positions your device. We then prepare the substantial equivalence comparison table, documenting intended use, technological characteristics, and performance data on a side-by-side basis. Where differences in technological characteristics exist, we identify what performance data is needed to demonstrate equivalent safety and effectiveness.

For devices without a suitable predicate, or where FDA classification is unclear, we evaluate whether Reclassification (De Novo) under Section 513(f)(2) is the appropriate pathway. De Novo results in a new classification with special controls and creates its own predicate for future 510(k) submitters.

Predicate Search Report

Documented search of the 510(k) database with evaluation of candidate predicates, recommendation of primary and fallback predicates, and rationale.

Substantial Equivalence Matrix

Side-by-side comparison of intended use, indications, technological characteristics, and performance data between your device and the selected predicate.

Pathway Decision Memo

Written assessment of whether 510(k), De Novo, or PMA is the appropriate pathway, with reasoning and risk tradeoffs for each option.

510(k)Section 513(f)(2)21 CFR 807 Subpart EPredicate DeviceNSEAI Request
510(k) Submission Preparation

FDA's eSTAR (electronic Submission Template and Resource) format is now required for most 510(k) submissions. The eSTAR template is a structured PDF that walks through each required section: device description, intended use and indications, substantial equivalence discussion, standards conformance, performance testing, biocompatibility, software, sterility and shelf life, and labelling. Each section requires specific content and cross-references to supporting data.

We prepare the complete eSTAR submission package, including a cover letter, summary, device description with images, 510(k) summary per 21 CFR 807.92, and all technical sections. We coordinate performance testing protocols and review test reports before submission. Software submissions require a Software Documentation Level (Basic or Enhanced) determination per FDA's 2021 software guidance; SaMD submissions require additional documentation per the SaMD action plan.

For international submissions where you hold a CE mark or PMDA approval, we assess whether FDA's international recognition programme or relevant third-party review organisation programmes can streamline the review process.

eSTAR Package

Complete FDA eSTAR-format submission with all required sections populated, cross-referenced to supporting test data and labelling.

Performance Testing Protocols

Test protocols aligned with applicable FDA guidance and recognised standards (ASTM, ISO, IEC), designed to generate data that directly addresses 510(k) review questions.

Software Documentation

Software description, level determination memo, hazard analysis, and verification and validation summary per FDA software guidance documents.

FDA Pre-Sub Package

If a Pre-Submission (Q-Sub) meeting is advisable, preparation of the briefing document and specific questions for FDA feedback before the main submission.

eSTAR21 CFR 807.92510(k) SummarySoftware LevelPre-SubQ-Sub
De Novo Classification

The De Novo pathway under 21 CFR Part 860 Subpart D is used when a device is of a type not previously classified and FDA determines it is low-to-moderate risk. A successful De Novo results in the device being classified into Class I or Class II with specific controls established in the De Novo order, and creates a legally marketed device that can serve as a predicate for future 510(k) submissions.

De Novo submissions require all the elements of a 510(k) plus a proposed classification, proposed special controls, and a summary of a risk-benefit analysis supporting Class II (rather than Class III PMA) classification. FDA's review clock for De Novo is 150 days from acceptance. We prepare the complete De Novo request including the proposed classification regulation language and special controls documentation.

De Novo Request Package

Complete De Novo submission per 21 CFR 860.260 including device description, proposed classification, special controls, and benefit-risk summary.

Special Controls Proposal

Proposed special controls language designed to be acceptable to FDA while not creating unnecessary compliance burden for future Class II devices.

21 CFR 860De Novo OrderSpecial ControlsClass II150-Day Clock
How an engagement works
01
Pathway & Predicate Selection
Identify the correct regulatory pathway and optimal predicate before any documents are drafted.
02
Pre-Sub (if needed)
For novel devices or complex performance questions, a Q-Sub meeting with FDA is prepared and submitted.
03
Submission Build & Review
eSTAR package assembled, reviewed internally for completeness, and submitted via the FDA Electronic Submissions Gateway.
04
Review Management
AI requests answered within the 90-day clock. Decision letter received and clearance file maintained.

Ready to move forward?

Share your device description and any existing test data. We will identify the right predicate and submission approach within a week.